Page language:

  • pl
  • en
32-050 Skawina, ul. Józefa Piłsudskiego 57B
biuro@manex.com.pl +48 (12) 631 10 70

MXC 1000HF 0,6/1kV


Cables for railway rolling stock, power, and signaling cables with special resistance to fire. These cables are laid in protected installations inside and outside rail vehicles, used for connecting stationary and moving parts.


Technical Data

  • Conductor: Copper, class 5 (as per EN 60228)
  • Insulation: Halogen-free polyolefin compound (HFFR)
  • Nominal Voltage:
    – AC Voltage: U0/U 600/1000V
    – DC Voltage: U0/U 900/1500V
  • Bending Radius of Cable [mm]:
    – For Fixed Installations:
    D ≤ 10mm: 3 x D
    D > 10mm: 4 x D
    – For Occasional Movements:
    D ≤ 10mm: 5 x D
    D > 10mm: 6 x D
    – For Frequent Movements:
    10 x D
    Where D is the cable diameter.
  • Maximum Continuous Operating Temperature: 100°C

Standards / Specifications

  • PN-K 02511:2000
  • EN45545

It meets the requirements of the REACH Regulation and the RoHS Directive.


Nominal Cross-Section Diameter of Single Wire (max.) Resistance at 20°C (max.) Insulation Wall Thickness (nom.) External Cable Diameter (max.)
1.00 mm² 0.21 mm 19.5 mΩ/m 0.6 mm 2.35 mm
1.50 mm² 0.26 mm 13.3 mΩ/m 0.6 mm 2.60 mm
2.50 mm² 0.26 mm 7.98 mΩ/m 0.6 mm 3.20 mm
4.00 mm² 0.31 mm 4.95 mΩ/m 0.6 mm 3.85 mm
6.00 mm² 0.31 mm 3.30 mΩ/m 0.8 mm 4.55 mm
10.00 mm² 0.41 mm 1.91 mΩ/m 1.0 mm 5.70 mm
16.00 mm² 0.41 mm 1.21 mΩ/m 1.25 mm 7.15 mm
25.00 mm² 0.41 mm 0.78 mΩ/m 1.25 mm 8.70 mm
35.00 mm² 0.41 mm 0.554 mΩ/m 1.25 mm 10.00 mm
50.00 mm² 0.41 mm 0.386 mΩ/m 1.45 mm 11.70 mm
70.00 mm² 0.41 mm 0.272 mΩ/m 1.90 mm 14.05 mm
95.00 mm² 0.41 mm 0.206 mΩ/m 1.50 mm 15.65 mm
120.00 mm² 0.41 mm 0.161 mΩ/m 1.50 mm 17.60 mm

Other Products: